REC315-3840 |
29 - Operational Health and Safety
29 - Operational Health and Safety
|
That, in order to ensure firefighter sustenance is of sufficient volume and quality, the NSW RFS reviews food standards and procedures in consultation with volunteers. The review should include catering service standards, including food safety, as well as the viability of sourcing commercial contracts and providing 12-hour food packs to firefighters.
|
REC315-3847 |
17 - Assets and technology
17 - Assets and technology
|
That, in order to ensure Australia’s fire fighting aerial capacity capitalises on existing assets and is made up of the right mix, Government:
a) request the Commonwealth to conduct a trial with NSW RFS on the feasibility of retrofitting RAAF C130 aircraft with modular airborne fire fighting systems to provide the Australian Defence Force with the capacity to augment aerial fire fighting during major disasters
b) work with states and territories through the National Aerial Firefighting Centre to review the current mix of aviation assets and determine whether it is fit-for-purpose, noting the current lack of mid-sized fire fighting aircraft.
|
REC315-3803 |
16 - Training and behaviour
16 - Training and behaviour
|
That Government support training initiatives to increase the capacity of fire authorities to fight the kind of megafires seen in the 2019-20 season. The training initiatives should include:
a) targeted training in local weather effects for fire behaviour analysts who are embedded in Incident Management Teams
b) an increase in the number of trained fire behaviour analysts so that, should there be a repeat of the scale of these fires, all Incident Management Teams can have an embedded analyst and there is some redundancy under more normal conditions
c) training of more meteorologists in fire behaviour so there are more expert resources available to embed within the NSW RFS State Operations Centre
d) dedicated training for firefighters in extreme fire behaviour
e) support for research training in challenging firefighting problems.
|
REC315-3854 |
7 - Inter-agency communication
7 - Inter-agency communication
|
That, in order to ensure emergency response agencies can communicate across state and territory borders, the Commonwealth Government allocate 10 + 10 MHz as a dedicated spectrum for Public Safety Mobile Broadband (PSMB) at no cost to states and territories.
|
REC315-3831 |
26 - Research
26 - Research
|
That, in order to capture and understand the impacts of bush fire smoke better, Government invest in operational air quality forecasting and alert systems, and public health research and policy development. This would involve investment to:
- develop a comprehensive system of forecasting and alerts for air quality incidents and all pollutants of concern, including but not limited to bush fire smoke, ozone and dust, and which is ideally nationally consistent
- investigate further the health impacts of bush fire smoke, based on improved data collection and including research on the long-term health impacts of poor air quality as a result of sustained exposure to severe bush fire smoke, particularly for vulnerable and at- risk segments of the community (children, elderly, firefighters, etc).
|
REC315-3839 |
29 - Operational Health and Safety
29 - Operational Health and Safety
|
That, to ensure firefighters can access mental health support through GPs, Government work with the Commonwealth Government to:
a) provide a free mental health screen to firefighters post-fire event and waive any gap payments if additional treatment is required
b) create a new Medicare Benefits Scheme item number to enable Governments to track demand for mental health services from firefighters over time and ensure an appropriate level of support is available.
|
REC315-3846 |
12 - EM agency and authority
12 - EM agency and authority
|
That, in order to maximise the efficiency and effectiveness of heavy plant used in dry fire fighting techniques, the NSW RFS expand and introduce the following in respect to heavy plant:
a) increase the number of trained Heavy Plant Supervisors and Managers to ensure an appropriate level of supervision in future significant fire seasons and to facilitate better the identification and tasking of appropriate localised heavy plant contractors; and review the feasibility of linkage to the SAP system for invoicing improvements. This should be introduced prior to the 2020-21 fire season
b) expand ARENA software to include the Heavy Plant Register, including the introduction
of GPS tracking for all agency and contracted plant, to improve contractual compliance
c) review the existing contractual process to ensure all heavy plant is categorised into types, size and functionality along with exploring potential for a standardised hourly rate for that category of equipment
d) work with Soil Conservation Service to ensure appropriate standards for the engagement and management of heavy plant to deliver safe and effective heavy plant service, including the delivery of standards and auditing.
|
REC315-3802 |
26 - Research
26 - Research
|
That Government establish NSW as a major world centre of bush fire research, and technology development and commercialisation. This should include:
a) establishing a Bush Fire Technology Fund, modelled on the Medical Devices Fund, to assist with the rapid development of technologies and services to sense, fight, mop up after and protect from bush fires
b) commissioning further research into extreme fire behaviour and building up the research and research training capacity in this field. This will improve our ability to understand, model and predict the likelihood of extreme fire behaviour in the landscape and enable targeting of fire fighting resources to areas where fires are likely to become most damaging.
|
REC315-3853 |
7 - Inter-agency communication
7 - Inter-agency communication
|
That, in order to ensure the State Emergency Operations Centre (SEOC) can maintain communications during emergencies, the Government provide the SEOC with independent Public Safety Network functionality.
|
REC315-3818 |
26 - Research
26 - Research
|
That, in order to improve understanding of optimal hazard reduction techniques and their application in the landscape:
a) Government extend the recently introduced program of mitigation crews so that hazard reduction activities can be undertaken when conditions are optimal (throughout the week and potentially at night)
b) all fire authorities review prescribed burning techniques and their implementation, and
commission further research into optimal prescribed burning regimes and techniques. This should include research to understand critical thresholds that, when breached, may render fuel treatment ineffective (i.e. fuel moisture thresholds), and the short, medium and long-term outcomes of hazard reduction burning regimes
c) Government commission research into a range of other hazard reduction techniques to understand better the cost versus benefit and effectiveness of different practices in various circumstances, including grazing.
|
REC315-3838 |
29 - Operational Health and Safety
29 - Operational Health and Safety
|
That, in order to ensure all NSW RFS members can access the mental health support they need, the NSW RFS expands in-house mental health support for members.
|
REC315-3868 |
33 - Relief and recovery
33 - Relief and recovery
|
That, in order to ensure people only need to tell their story once to access government agency support following an emergency, Resilience NSW and Service NSW jointly design an inclusive, person-centred approach to information collection at evacuation centres. This should be supported by an opt-in scheme enabling personal information to be shared between NSW government agencies, local councils and non-governmental organisations administering support services for disaster-affected people.
|
REC315-3845 |
26 - Research
26 - Research
|
That Government commission further research on the potential risks and benefits of backburning during severe, extreme and catastrophic conditions and/or in particular terrain, and that the NSW RFS use this research to inform future backburning protocols and training.
|
REC315-3852 |
7 - Inter-agency communication
7 - Inter-agency communication
|
That, in order to improve fireground communications between NSW agencies and interstate personnel: a) Government ensure all NSW fire authority personnel and vehicles can access and utilise the Public Safety Network (PSN). This should include access to NSW RFS Private Mobile Radio networks where PSN coverage is not yet available.
b) the NSW Telco Authority review cross-border communications availability and planning and advise NSW fire authorities on next steps to enable multi-state interoperability for wide area communications.
|
REC315-3815 |
17 - Assets and technology
17 - Assets and technology
|
That, in order to equip NSW RFS with comprehensive information on all structures and assets at risk of bush fire, Government ensures that:
- there is a single whole-of-government procurement and acquisition program for imagery and LiDAR and that Government accelerate the building of the State Digital Twin and associated Digital Workbench
- owners/managers of assets (apart from private home owners whose information will be provided through local councils) in bush fire prone land are required to provide to the Digital Twin at least the following information/metadata with quality control certification on an annual basis (with annual census at least two months before the start of the fire season):
* precise geolocation
* description of asset including picture
* value level
* fire treatment on asset
* Asset Protection Zone (APZ) details and how it is maintained
* access details
* what redundancy is available if relevant
* any metadata requirements specific to the asset class
* emergency contact and instructions on how to access where more information is held
* any restrictions on data access and sharing.
The Digital Twin must also be able to incorporate:
- information about the hazard reduction results for road verges, fire trails, APZs and other defendable space
- local information supplied by organisations such as local NSW RFS brigades.
|
REC315-3837 |
17 - Assets and technology
17 - Assets and technology
|
That, in order to improve firefighter safety, Government fire authorities:
a) ensure all light tankers used as part of active frontline bush fire fighting operations are fitted with a single point crew protection safety spray system and radiant heat protection blankets as a minimum standard across all NSW fire authorities
b) ensure all medium/heavy tankers are fitted with radiant heat protection blankets, wheel and ‘halo’ sprays fitted as a minimum standard across all NSW fire authorities
c) undertake additional research to determine the most appropriate cabin protection for the different frontline vehicles.
d) provide ongoing investment for NSW RFS fleet upgrades.
|
REC315-3861 |
16 - Training and behaviour
16 - Training and behaviour
|
That, in order to expand the pool of trained personnel able to undertake the Public Information Functional Area Coordinator (PIFAC) role, Resilience NSW and the NSW Police Media Unit (PIFAC) develop and deliver a training package for Emergency Management Media Liaison Officers.
|
REC315-3843 |
17 - Assets and technology
17 - Assets and technology
|
That, in order to improve early fire suppression, the NSW RFS trial initial aerial dispatch in areas of high bush fire risk. The trial should identify the most appropriate and cost-effective mix of aircraft, and any associated infrastructure improvements that would be required.
|
REC315-3849 |
17 - Assets and technology
17 - Assets and technology
|
That, in order to enhance NSW’s fire fighting capacity, Government trial aerial fire fighting at night in the 2020-21 season with a view to full implementation if successful.
|
REC315-3808 |
22 - Role of local Gvt
22 - Role of local Gvt
|
That, in order to strengthen the capability of local councils in future emergency events:
a) Resilience NSW, in consultation with local government, develop specific training that focuses on the role, responsibilities and expected functions of the Local Emergency Management Officer (LEMO), including regular ‘refresher’ components
b) Councils support their staff to participate in LEMO training on an ongoing basis, and ensure that staff who are LEMOs are appropriately senior and have the authority to commit resources.
|
REC315-3836 |
17 - Assets and technology
17 - Assets and technology
|
That, in order to ensure frontline personnel have appropriate personal protective clothing during bush fires:
a) FRNSW review the current design of its bush fire jacket, noting improvements that have been made since 2002 that meet AS/NZS4824:2006 Protective clothing for firefighters, and increase the allocation of bush fire coats to two jackets per member
b) NSW RFS issue two sets of personal protective clothing to operational members, and others as appropriate.
|
REC315-3857 |
12 - EM agency and authority
12 - EM agency and authority
|
That, in order to ensure timely payment and maintain positive ongoing supplier relationships during large-scale bush fires, the NSW RFS implements an automated logistics solution, informed by the outcomes of the Emergency Logistics Project.
|
REC315-3841 |
12 - EM agency and authority
12 - EM agency and authority
|
That, in order to ensure suitably skilled and experienced personnel operate as Divisional Commanders during major fire incidents, Bush Fire Management Committees identify appropriate personnel as part of their plan of operations.
|
REC315-3848 |
17 - Assets and technology
17 - Assets and technology
|
That, in order to enhance NSW’s ability to improve situational awareness, Government expand FRNSW’s Remotely Piloted Aerial Systems (RPAS) capability (both capital assets and trained operators) to major regional centres and ensure the NSW RFS and other NSW government agencies can access this capability as required.
|
REC315-3807 |
16 - Training and behaviour
16 - Training and behaviour
|
That, in order to expand NSW’s specialist aviation personnel safety and capacity, Government expand simulator capabilities at the NSW RFS Training Academy.
|
REC315-3834 |
12 - EM agency and authority
12 - EM agency and authority
|
That, in order to ensure all firefighters understand how local situational awareness reflects (or may not reflect) the broader scale situation presented by a large/extreme bush fire and the implications this may have on asset protection and fire suppression strategies, the NSW RFS:
a) develops information packages for all types of operating environments to improve out-of- area crews’ understanding of the local terrain and fuels, and distributes information to out-of-area crew members from all fire authorities
b) accelerates the roll out of Mobile Data Terminals into all fire fighting vehicles to improve delivery of briefings and incident information/intelligence to field commanders.
|
REC315-3855 |
7 - Inter-agency communication
7 - Inter-agency communication
|
That, in order to ensure all agencies have a clear understanding of cross-border communication channels during bush fires, all MoUs between state or territory agencies include an agreed protocol about how agencies will communicate across borders and that these are reflected in Incident Action Plans.
|